{"id":41996,"date":"2022-11-02T15:21:48","date_gmt":"2022-11-02T14:21:48","guid":{"rendered":"https:\/\/iul-instruments.com\/?p=41996"},"modified":"2022-11-14T10:43:31","modified_gmt":"2022-11-14T09:43:31","slug":"kann-ein-lateral-flow-reader-quantifizieren","status":"publish","type":"post","link":"https:\/\/iul-instruments.com\/de\/kann-ein-lateral-flow-reader-quantifizieren\/","title":{"rendered":"Kann ein Lateral Flow Reader quantifizieren?"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8220;1&#8243; admin_label=&#8220;section&#8220; _builder_version=&#8220;4.16&#8243; global_colors_info=&#8220;{}&#8220;][et_pb_row admin_label=&#8220;row&#8220; _builder_version=&#8220;4.16&#8243; background_size=&#8220;initial&#8220; background_position=&#8220;top_left&#8220; background_repeat=&#8220;repeat&#8220; global_colors_info=&#8220;{}&#8220;][et_pb_column type=&#8220;4_4&#8243; _builder_version=&#8220;4.16&#8243; custom_padding=&#8220;|||&#8220; global_colors_info=&#8220;{}&#8220; custom_padding__hover=&#8220;|||&#8220;][et_pb_text admin_label=&#8220;Text&#8220; _builder_version=&#8220;4.18.0&#8243; background_size=&#8220;initial&#8220; background_position=&#8220;top_left&#8220; background_repeat=&#8220;repeat&#8220; global_colors_info=&#8220;{}&#8220;]<\/p>\n<p>Bei den Lateral-Flow-Tests, auch Lateral-Flow-Immunoassays oder Schnelltests genannt, handelt es sich um\u00a0<strong>Medizinprodukte, die dazu dienen, das Vorhandenseins einer Substanz in einer fl\u00fcssigen Probe nachzuweisen, und zwar ohne die Hilfe spezieller Ger\u00e4te<\/strong>. Das Ergebnis eines Lateral-Flow-Tests kann einfach und ohne spezielle Schulung abgelesen werden. Wie jedoch kann ein solcher Test quantitative Ergebnisse liefern? Mit einem Lateral-Flow-Streifenleser.<\/p>\n<p>Das menschliche Auge ist in der Lage, entsprechend der Intensit\u00e4t der Testlinie (Reaktion) eine semiquantitative Auswertung vorzunehmen. Um eine Aussage dar\u00fcber zu machen, ob das Ergebnis stark positiv oder schwach positiv ist, ist jedoch der Vergleich mit einer Referenzskala erforderlich. Au\u00dferdem ist das Ergebnis immer subjektiv, das hei\u00dft, von der Sehsch\u00e4rfe des Anwenders und den Umgebungsbedingungen\/Lichtverh\u00e4ltnissen abh\u00e4ngig.\u00a0<strong>Ein Lateral-Flow-Streifenleser kann, unter Verwendung einer Kalibrierkurve, ein objektives, semiquantitatives und sogar vollquantitatives Ergebnis liefern.<\/strong><\/p>\n<p>Die semiquantitative Methode erm\u00f6glicht die Festlegung unterschiedlicher Grenzwerte f\u00fcr ein starkes bzw. schwaches Ergebnis. Der unterste Grenzwert entspricht dem Minimalwert, bei dem die Reaktion ein sichtbares Ergebnis liefert bzw. bei dem die Testlinie als vorhanden eingestuft wird. Entsprechend wird das Ergebnis\u00a0<strong>bei \u00dcberschreitung des oberen Grenzwertes als stark positiv und darunter als schwach positiv eingestuft.<\/strong><\/p>\n<h2><strong>Wie erfolgt die Quantifizierung bei einem Lateral-Flow-Streifenleser?<\/strong><\/h2>\n<p>Die Quantifizierung der Testlinie (Reaktion) erfolgt bei einem Lateral-Flow-Streifenleser \u00fcber die Analytkonzentration in der Probe. Zu diesem Zweck\u00a0<strong>verwendet der Streifenleser vorg\u00e4ngig, anhand von wiederholten Messungen von Standardl\u00f6sungen mit bekannter Konzentration erstellte Kalibrierkurven<\/strong>. Die Kalibrierkurve ber\u00fccksichtigt die Dynamik der Probe und deckt den gesamten Messbereich ab, womit der Streifenleser bereit ist, qualitative, semiquantitative oder vollquantitative Ergebnisse zu interpretieren.<\/p>\n<p><strong>Der Lateral-Flow-Streifenleser wandelt die \u201eRohantwort\u201c (Intensit\u00e4t der Testlinie) \u00fcber die Kalibrierkurve in ein quantitatives Ergebnis (z. B. eine Konzentration) um.<\/strong> Bei einigen quantitativen Methoden erfolgt eine Normierung der Reaktion (Testlinie\/Kontrolllinie), bevor der Algorithmus ausgef\u00fchrt wird. Die Algorithmen unterscheiden sich von Streifenleser zu Streifenleser. Die am h\u00e4ufigsten angewandte Methode ist die 4-Parameter-Logistik-Funktion (4 PL). Daneben gibt es die Sprungfunktion, die Methode der kleinsten Quadrate und die lineare Regression.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture8.jpg\" width=\"903\" height=\"333\" alt=\"\" class=\"wp-image-42003 aligncenter size-full\" srcset=\"https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture8.jpg 903w, https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture8-480x177.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 903px, 100vw\" \/><\/p>\n<h2><strong>iPeak von IUL <\/strong>\u2013<strong> Ein kolorimetrisches Lateral-Flow-Leseger\u00e4t<\/strong><\/h2>\n<p>Beim <a href=\"https:\/\/iul-instruments.com\/mediul\/ready-to-use-ipeak\/\"><strong>iPeak\u00ae von IUL<\/strong><\/a>\u00a0handelt es sich um einen kolorimetrischen Schnelltestleser, der die Farben Ihrer Tests verst\u00e4rkt. Der iPeak\u00ae ist mit der Flash-Eye-Technologie ausgestattet und liefert damit reproduzierbare und wiederholbare Ergebnisse. Die Ergebnisse k\u00f6nnen exportiert und ausgedruckt, in Echtzeit versandt\u00a0und, mit nur einem Klick, in Ihr Laborinformationssystem (LIS) integriert oder an Ihren Server \u00fcbermittelt werden.<\/p>\n<p>Das Konzept der Flash-Eye-Technologie basiert auf der auf den Prinzipien der Machine-Vision-Beleuchtung basierenden Dombeleuchtung (auch schattenfreie Beleuchtung oder Cloudy-Day-Beleuchtung genannt).\u00a0Die Kamera des iPeak\u00ae macht eine Aufnahme des LED-beleuchteten Tests, w\u00e4hrend die geometrische Position der LED-Leuchten, die extensiv erforscht wurde, <strong>\u00a0eine pr\u00e4zise und gleichm\u00e4\u00dfige Beleuchtung gew\u00e4hrleistet.<\/strong><\/p>\n<p>Die Technologie verhindert Reflexionen und Schatten und verteilt diffuses und homogenes Licht in einer Kammer,<strong>\u00a0was den\u00a0iPeak\u00ae zum besten Schnelltestleser macht<\/strong>.\u00a0Ein hauseigener Algorithmus, der auf in der Radartechnologie verwendeten Verfahren basiert (die auch sehr schwache Signale in ger\u00e4uschvoller Umgebung erkennen), verarbeitet das Bild und erh\u00f6ht die Zuverl\u00e4ssigkeit der Ergebnisse.<\/p>\n<p>Mit anderen Worten: Die Wissenschaft hinter dem iPeak\u00ae zeichnet ihn aus und macht ihn einzigartig.\u00a0<strong>Ansatzpunkt und Ziel ist maximale Sensitivit\u00e4t, um die Linien (Kontroll-\/Testlinien) von Lateral-Flow-Assays (Lateral-Flow-Tests) zu erkennen und sogar zu quantifizieren<\/strong>.\u00a0Der iPeak\u00ae steht f\u00fcr die Verschmelzung von Mathematik und Physik zu einem ultimativen Lateral-Flow-Leseger\u00e4t.<\/p>\n<h2><strong>Die quantitativen Methoden des iPeak\u00ae<\/strong><\/h2>\n<p>Derzeit liefert der iPeak\u00ae zus\u00e4tzlich zu qualitativen<strong> auch quantitative Ergebnisse<\/strong>, wobei 4 unterschiedliche Methoden verwendet werden, die bei Bedarf alle eine vorg\u00e4ngige Normierung der Testlinie auf die Kontrolllinie zulassen:<\/p>\n<ul>\n<li><strong>5 PL, 4 PL:\u00a0<\/strong>Bei der 4-Parameter-Logistik-Funktion handelt es sich um ein Regressionsmodell mit einem sigmoidalen oder \u201cs-f\u00f6rmigen\u201d Kurvenverlauf. Viele Bioassays verhalten sich so, das hei\u00dft, die Reaktion verl\u00e4uft nur in einem bestimmten Bereich der Kurve linear.<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture9.jpg\" width=\"738\" height=\"441\" alt=\"\" class=\"wp-image-42007 aligncenter size-full\" srcset=\"https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture9.jpg 738w, https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture9-480x287.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 738px, 100vw\" \/><\/p>\n<ul>\n<li><strong>Sprungfunktion:<\/strong>\u00a0Bei der Sprungfunktion sind 5 Parameter erforderlich. Der f\u00fcr P1, P3 und P5 gew\u00e4hlte Text (z. B. mittelstark, schwach positiv, stark positiv) erscheint in \u00dcbereinstimmung mit den als P2 und P4 festgelegten Grenzwerten.<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture10.jpg\" width=\"846\" height=\"504\" alt=\"\" class=\"wp-image-42011 aligncenter size-full\" srcset=\"https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture10.jpg 846w, https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture10-480x286.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 846px, 100vw\" \/><\/p>\n<ul>\n<li><strong>Methode der kleinsten Quadrate:<\/strong>\u00a0Polynom 2. Grades.<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture11.jpg\" width=\"843\" height=\"502\" alt=\"\" class=\"wp-image-42015 aligncenter size-full\" srcset=\"https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture11.jpg 843w, https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture11-480x286.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 843px, 100vw\" \/><\/p>\n<ul>\n<li><strong>Lineare Regression:<\/strong> Polynom 1. Grades<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture12.jpg\" width=\"798\" height=\"477\" alt=\"\" class=\"wp-image-42019 aligncenter size-full\" srcset=\"https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture12.jpg 798w, https:\/\/iul-instruments.com\/wp-content\/uploads\/2022\/11\/Picture12-480x287.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 798px, 100vw\" \/><\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Bei den Lateral-Flow-Tests, auch Lateral-Flow-Immunoassays oder Schnelltests genannt, handelt es sich um\u00a0Medizinprodukte, die dazu dienen, das Vorhandenseins einer Substanz in einer fl\u00fcssigen Probe nachzuweisen, und zwar ohne die Hilfe spezieller Ger\u00e4te. Das Ergebnis eines Lateral-Flow-Tests kann einfach und ohne spezielle Schulung abgelesen werden. Wie jedoch kann ein solcher Test quantitative Ergebnisse liefern? Mit einem Lateral-Flow-Streifenleser. [&hellip;]<\/p>\n","protected":false},"author":96,"featured_media":41997,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"Bei den Lateral-Flow-Tests, auch Lateral-Flow-Immunoassays oder Schnelltests genannt, handelt es sich um\u00a0<strong>Medizinprodukte, die dazu dienen, das Vorhandenseins einer Substanz in einer fl\u00fcssigen Probe nachzuweisen, und zwar ohne die Hilfe spezieller Ger\u00e4te<\/strong>. Das Ergebnis eines Lateral-Flow-Tests kann einfach und ohne spezielle Schulung abgelesen werden. Wie jedoch kann ein solcher Test quantitative Ergebnisse liefern? Mit einem Lateral-Flow-Streifenleser.\r\n\r\nDas menschliche Auge ist in der Lage, entsprechend der Intensit\u00e4t der Testlinie (Reaktion) eine semiquantitative Auswertung vorzunehmen. Um eine Aussage dar\u00fcber zu machen, ob das Ergebnis stark positiv oder schwach positiv ist, ist jedoch der Vergleich mit einer Referenzskala erforderlich. Au\u00dferdem ist das Ergebnis immer subjektiv, das hei\u00dft, von der Sehsch\u00e4rfe des Anwenders und den Umgebungsbedingungen\/Lichtverh\u00e4ltnissen abh\u00e4ngig.\u00a0<strong>Ein Lateral-Flow-Streifenleser kann, unter Verwendung einer Kalibrierkurve, ein objektives, semiquantitatives und sogar vollquantitatives Ergebnis liefern.<\/strong>\r\n\r\nDie semiquantitative Methode erm\u00f6glicht die Festlegung unterschiedlicher Grenzwerte f\u00fcr ein starkes bzw. schwaches Ergebnis. Der unterste Grenzwert entspricht dem Minimalwert, bei dem die Reaktion ein sichtbares Ergebnis liefert bzw. bei dem die Testlinie als vorhanden eingestuft wird. Entsprechend wird das Ergebnis\u00a0<strong>bei \u00dcberschreitung des oberen Grenzwertes als stark positiv und darunter als schwach positiv eingestuft.<\/strong>\r\n<h2><strong>Wie erfolgt die Quantifizierung bei einem Lateral-Flow-Streifenleser?<\/strong><\/h2>\r\nDie Quantifizierung der Testlinie (Reaktion) erfolgt bei einem Lateral-Flow-Streifenleser \u00fcber die Analytkonzentration in der Probe. Zu diesem Zweck\u00a0<strong>verwendet der Streifenleser vorg\u00e4ngig, anhand von wiederholten Messungen von Standardl\u00f6sungen mit bekannter Konzentration erstellte Kalibrierkurven<\/strong>. Die Kalibrierkurve ber\u00fccksichtigt die Dynamik der Probe und deckt den gesamten Messbereich ab, womit der Streifenleser bereit ist, qualitative, semiquantitative oder vollquantitative Ergebnisse zu interpretieren.\r\n\r\n<strong>Der Lateral-Flow-Streifenleser wandelt die \u201eRohantwort\u201c (Intensit\u00e4t der Testlinie) \u00fcber die Kalibrierkurve in ein quantitatives Ergebnis (z. B. eine Konzentration) um.<\/strong> Bei einigen quantitativen Methoden erfolgt eine Normierung der Reaktion (Testlinie\/Kontrolllinie), bevor der Algorithmus ausgef\u00fchrt wird. Die Algorithmen unterscheiden sich von Streifenleser zu Streifenleser. Die am h\u00e4ufigsten angewandte Methode ist die 4-Parameter-Logistik-Funktion (4 PL). Daneben gibt es die Sprungfunktion, die Methode der kleinsten Quadrate und die lineare Regression.\r\n<h2><strong>iPeak von IUL <\/strong>\u2013<strong> Ein kolorimetrisches Lateral-Flow-Leseger\u00e4t<\/strong><\/h2>\r\nBeim <a href=\"https:\/\/iul-instruments.com\/mediul\/ready-to-use-ipeak\/\"><strong>iPeak\u00ae von IUL<\/strong><\/a>\u00a0handelt es sich um einen kolorimetrischen Schnelltestleser, der die Farben Ihrer Tests verst\u00e4rkt. Der iPeak\u00ae ist mit der Flash-Eye-Technologie ausgestattet und liefert damit reproduzierbare und wiederholbare Ergebnisse. Die Ergebnisse k\u00f6nnen exportiert und ausgedruckt, in Echtzeit versandt\u00a0und, mit nur einem Klick, in Ihr Laborinformationssystem (LIS) integriert oder an Ihren Server \u00fcbermittelt werden.\r\n\r\nDas Konzept der Flash-Eye-Technologie basiert auf der auf den Prinzipien der Machine-Vision-Beleuchtung basierenden Dombeleuchtung (auch schattenfreie Beleuchtung oder Cloudy-Day-Beleuchtung genannt).\u00a0Die Kamera des iPeak\u00ae macht eine Aufnahme des LED-beleuchteten Tests, w\u00e4hrend die geometrische Position der LED-Leuchten, die extensiv erforscht wurde, <strong>\u00a0eine pr\u00e4zise und gleichm\u00e4\u00dfige Beleuchtung gew\u00e4hrleistet.<\/strong>\r\n\r\nDie Technologie verhindert Reflexionen und Schatten und verteilt diffuses und homogenes Licht in einer Kammer,<strong>\u00a0was den\u00a0iPeak\u00ae zum besten Schnelltestleser macht<\/strong>.\u00a0Ein hauseigener Algorithmus, der auf in der Radartechnologie verwendeten Verfahren basiert (die auch sehr schwache Signale in ger\u00e4uschvoller Umgebung erkennen), verarbeitet das Bild und erh\u00f6ht die Zuverl\u00e4ssigkeit der Ergebnisse.\r\n\r\nMit anderen Worten: Die Wissenschaft hinter dem iPeak\u00ae zeichnet ihn aus und macht ihn einzigartig.\u00a0<strong>Ansatzpunkt und Ziel ist maximale Sensitivit\u00e4t, um die Linien (Kontroll-\/Testlinien) von Lateral-Flow-Assays (Lateral-Flow-Tests) zu erkennen und sogar zu quantifizieren<\/strong>.\u00a0Der iPeak\u00ae steht f\u00fcr die Verschmelzung von Mathematik und Physik zu einem ultimativen Lateral-Flow-Leseger\u00e4t.\r\n<h2><strong>Die quantitativen Methoden des iPeak\u00ae<\/strong><\/h2>\r\nDerzeit liefert der iPeak\u00ae zus\u00e4tzlich zu qualitativen<strong> auch quantitative Ergebnisse<\/strong>, wobei 4 unterschiedliche Methoden verwendet werden, die bei Bedarf alle eine vorg\u00e4ngige Normierung der Testlinie auf die Kontrolllinie zulassen:\r\n<ul>\r\n \t<li><strong>5 PL, 4 PL:\u00a0<\/strong>Bei der 4-Parameter-Logistik-Funktion handelt es sich um ein Regressionsmodell mit einem sigmoidalen oder \u201cs-f\u00f6rmigen\u201d Kurvenverlauf. Viele Bioassays verhalten sich so, das hei\u00dft, die Reaktion verl\u00e4uft nur in einem bestimmten Bereich der Kurve linear.<\/li>\r\n<\/ul>\r\n<ul>\r\n \t<li><strong>Sprungfunktion:<\/strong>\u00a0Bei der Sprungfunktion sind 5 Parameter erforderlich. Der f\u00fcr P1, P3 und P5 gew\u00e4hlte Text (z. B. mittelstark, schwach positiv, stark positiv) erscheint in \u00dcbereinstimmung mit den als P2 und P4 festgelegten Grenzwerten.<\/li>\r\n<\/ul>\r\n<ul>\r\n \t<li><strong>Methode der kleinsten Quadrate:<\/strong>\u00a0Polynom 2. Grades.<\/li>\r\n<\/ul>\r\n<ul>\r\n \t<li><strong>Lineare Regression:<\/strong> Polynom 1. Grades<\/li>\r\n<\/ul>","_et_gb_content_width":""},"categories":[],"tags":[],"_links":{"self":[{"href":"https:\/\/iul-instruments.com\/de\/wp-json\/wp\/v2\/posts\/41996"}],"collection":[{"href":"https:\/\/iul-instruments.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/iul-instruments.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/iul-instruments.com\/de\/wp-json\/wp\/v2\/users\/96"}],"replies":[{"embeddable":true,"href":"https:\/\/iul-instruments.com\/de\/wp-json\/wp\/v2\/comments?post=41996"}],"version-history":[{"count":4,"href":"https:\/\/iul-instruments.com\/de\/wp-json\/wp\/v2\/posts\/41996\/revisions"}],"predecessor-version":[{"id":42461,"href":"https:\/\/iul-instruments.com\/de\/wp-json\/wp\/v2\/posts\/41996\/revisions\/42461"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/iul-instruments.com\/de\/wp-json\/wp\/v2\/media\/41997"}],"wp:attachment":[{"href":"https:\/\/iul-instruments.com\/de\/wp-json\/wp\/v2\/media?parent=41996"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/iul-instruments.com\/de\/wp-json\/wp\/v2\/categories?post=41996"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/iul-instruments.com\/de\/wp-json\/wp\/v2\/tags?post=41996"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}